Milwaukee Instruments Doll MA871 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mesure, test et contrôle Milwaukee Instruments Doll MA871. Milwaukee Instruments Doll MA871 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
www.milwaukeeinst.com
1
www.milwaukeeinst.com
MA871
INSTRUCTION MANUAL
Milwaukee RefractometerMilwaukee Refractometer
Milwaukee RefractometerMilwaukee Refractometer
Milwaukee Refractometer
Refractometer for SucroseRefractometer for Sucrose
Refractometer for SucroseRefractometer for Sucrose
Refractometer for Sucrose
MeasurementsMeasurements
MeasurementsMeasurements
Measurements
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - INSTRUCTION MANUAL

www.milwaukeeinst.com1www.milwaukeeinst.comMA871INSTRUCTION MANUALMilwaukee RefractometerMilwaukee RefractometerMilwaukee RefractometerMilwaukee Refra

Page 2 - TABLE OF CONTENTS

1010101010Instruction Manual MA871 Refractometer for Sucrose MeasurementsMEASUREMENT PROCEDUREVerify the instrument has been calibrated before taking

Page 3 - FUNCTIONAL DESCRIPTION

www.milwaukeeinst.com115. Using plastic pipettes, rinse prism and sample well with distilled or deionized water.Wipe dry. The instrument is ready for

Page 4

1212121212Instruction Manual MA871 Refractometer for Sucrose MeasurementsTo change the temperature measurement unit from Celsius to Fahrenheit (or vic

Page 5 - GENERAL DESCRIPTION

www.milwaukeeinst.com13ERROR MESSAGESedoCrorrEnoitpircseDrrEelcyC.eruliaflareneGfI.tnemurtsniotrewop,rorresahllitstnemurtsni.eekuawliMtcatnocOL yalpsi

Page 6 - SPECIFICATIONS

1414141414Instruction Manual MA871 Refractometer for Sucrose MeasurementsBATTERY REPLACEMENTTo replace the instrument’s battery, follow these steps:•

Page 7 - PRINCIPLE OF OPERATION

www.milwaukeeinst.com15WARRANTYThis instrument is warranted against defects in materials and manufacturing for a period of2 years from the date of pur

Page 8 - MEASUREMENT GUIDELINES

1616161616Instruction Manual MA871 Refractometer for Sucrose MeasurementsSales and Technical Service Contacts:Milwaukee s.r.l.C.so Leonardo da Vinci 4

Page 9 - CALIBRATION PROCEDURE

22222Instruction Manual MA871 Refractometer for Sucrose MeasurementsTABLE OF CONTENTSFUNCTIONAL DESCRIPTION ...

Page 10 - MEASUREMENT PROCEDURE

www.milwaukeeinst.com3FUNCTIONAL DESCRIPTIONDISPLAYDISPLAYDISPLAYDISPLAYDISPLAYA. BATTERY STATUS ICON (BLINKS WHEN LOW BATTERY CONDITION DETECTED)B. M

Page 11

44444Instruction Manual MA871 Refractometer for Sucrose MeasurementsH. BATTERY COVERI. BATTERY COMPARTMENTBOTTOMBOTTOMBOTTOMBOTTOMBOTTOMA. LIQUID CRYS

Page 12 - CHANGING TEMPERATURE UNIT

www.milwaukeeinst.com5GENERAL DESCRIPTIONSIGNIFICANCE OF USEThank you for choosing Milwaukee. This instruction manual will provide you the necessaryin

Page 13 - ERROR MESSAGES

66666Instruction Manual MA871 Refractometer for Sucrose MeasurementsRange 0 to 85% Brix 0 to 80 °C (32 to 175 °F)Resolution 0.1% Brix 0.1 °C (0.1 °F)A

Page 14 - BATTERY REPLACEMENT

www.milwaukeeinst.com7PRINCIPLE OF OPERATIONThe Brix determination is made by measuring the refractive index of a solution. RefractiveIndex is an opti

Page 15

88888Instruction Manual MA871 Refractometer for Sucrose MeasurementsMEASUREMENT GUIDELINES• Handle instrument carefully. Do not drop.• Do not immerse

Page 16 - THANK YOU FOR CHOOSING

www.milwaukeeinst.com9CALIBRATION PROCEDURECalibration should be performed daily, before measurements are made, when thebattery has been replaced, or

Commentaires sur ces manuels